Is it possible to use tower lights as both Steady and Flashing function?

LF” specification of Tower Light is available to use both Steady and Flashing function. In case of AC specification for ST45/56/80LF, Steady Common line and Flashing Common line are out from the product separately. Therefore the user can use both Steady and Flashing partitively according to connection (signal method) method (But when tie steady common line and flashing common line together, the PCB will be damaged. Therefore it needs for attentions. ex) when steady and flashing signal are input at same time, it is no problem for a while. But when it lasted continuously, misoperation will be happened or PCB board will be damaged). In case of DC specification, basically flashing common line is only out from the product. Therefore you have to connect separately by referring to connection diagram for using of steady. If you want to use steady by connecting of common line same as flashing, you have to order steady common line as option.

Please process as below for additional inquiry and purchsing
A. Online Purchasing Inquiry
1. Firstly check the information of the Products through “Website > Products > Products Group“.
2. Please put inquiry through “Website > Customer Support > Question and Reply“.

B. Offline Purchasing Inquiry
Please contact after checking of person in charge through “Website > Purchase > Purchasing from Abroad“.